BYTQN - KODAK EKTACHROME R-3 COLOR DEVELOPER REPLENISHER, SOLUTION
- MSDS: BYTQN
- Manufacturer: EASTMAN KODAK COMPANY
- Product Name: KODAK EKTACHROME R-3 COLOR DEVELOPER REPLENISHER, SOLUTION
- National Stock Number: 6750-00D004619
Product Identification
Product ID:KODAK EKTACHROME R-3 COLOR DEVELOPER REPLENISHER, SOLUTION
MSDS Date:12/08/1993
FSC:6750
NIIN:00D004619
Kit Part:Y
MSDS Number: BYTQN
Responsible Party
ROCHESTER, NY 14650
US
Emergency Phone: 716-722-5151
Info Phone: 800- 242-2424
Cage: 19139
Contractor
Telephone: 716-722-5151/(800) 242-2424
Cage: 19139
Ingredients
WATER
CAS: 7732-18-5
RTECS: ZC0110000
Fraction By Weight: 90-95%
POTASSIUM CARBONATE
CAS: 584-08-7
RTECS: TS7750000
Fraction By Weight: 1-5%
BENZYL ALCOHOL
CAS: 100-51-6
RTECS: DN3150000
Fraction By Weight: 1-5%
ETHYLENE GLYCOL
CAS: 25646-71-3
RTECS: PB0431000
Fraction By Weight: <1%
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
Hazards
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION: EXPECTED TO BE A LOW
HAZARD FOR RECOMMENDED HANDLING. EYES: CAUSES IRRITATION. SKIN:
CAUSES IRRITATION. MAY CAUSE ALLERGIC SKIN REACTION. INGESTION:
EXPECTED TO BE A LOW INGESTION HAZARD.
Explanation of Carcinogenicity:NO INGREDIENT OF A CONCENTRATION OF 0.1%
OR GREATER IS LISTED AS A CARCINOGEN OR SUSPECTED CARCINOGEN.
Effects of Overexposure:NONE SPECIFIED BY MANUFACTURER.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:INHALATION-IF SYMPTOMATIC, MOVE TO FRESH AIR. GET MEDICAL
ATTENTION IF SYMPTOMS PERSISTS. EYES-IMMEDIATELY FLUSH WITH PLENTY
OF WATER FOR AT LEAST 15 MIN. GET MEDICAL ATTENTION.
SKIN-IMMEDIATELY FLUSH WITH PLENTY OF WATER & WASH WITH A
NON-ALKALINE SKIN CLEANER. GET MEDCIAL ATTENTION. INGESTED-DRINK 1
TO 2 GLASSES OF WATER. SEEK MEDICAL ATTENTION.
Fire Fighting
Flash Point:NONE
Extinguishing Media:USE APPROPIATE AGENT FOR ADJACENT FIRE.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS AND
PROTECTIVE CLOTHING.
Unusual Fire/Explosion Hazard:NONE.
Accidental Release
Spill Release Procedures:FLUSH TO SEWER WITH LARGE AMOUNTS OF WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:KEEP CONTAINER CLOSED.
Other Precautions:THE ROUTINE USE OF A NONALKALINE (ACID) TYPE OF HAND
CLEANER AND REGULAR CLEANING OF WORKING SURFACES, GLOVES, ETC. WILL
HELP MINIMIZE THE POSSIBILITY OF A SKIN REACTION.
Exposure Controls
Respiratory Protection:NONE SHOULD BE NEEDED.
Ventilation:GOOD GENERAL VENTILATION (10 AIR CHANGES PER HOUR) SHOULD
BE USED. VENTILATION RATES SHOULD BE MATCHED TO CONDITIONS.
Protective Gloves:IMPERVIOUS GLOVES SHOULD BE WORN.
Eye Protection:SAFETY GLASSES WITH SIDE SHIELD.
Other Protective Equipment:WEAR PROTECTIVE CLOTHING APPROPIATE FOR THE
RISK OF EXPOSURE. EYE BATH, WASHING FACILITIES, SAFETY SHOWER.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
KEY 1: C1. THIS ITEM CONTAINS THREE PARTS. ECOLOGICAL INFORMATION: THIS
MATERIAL, ITSELF, HAS NOT BEEN TESTED FOR ENVIRONMENTAL EFFETCS.
THIS MATERIAL FORMS A MODERATELT AQUEOUS SOLUTION, AND THIS PRO
PERTY MAY CAUSE ADVERSE ENVIRONMENTAL EFFECTS.
Chemical Properties
HCC:N1
Boiling Pt:B.P. Text:>212F,>100C
Vapor Pres:23.4 MBAR
Vapor Density:0.6
Spec Gravity:1.034
pH:10.5
Solubility in Water:COMPLETE
Appearance and Odor:LIQUID, COLORLESS, ODORLESS.
Percent Volatiles by Volume:90-95
Stability
Stability Indicator/Materials to Avoid:YES
NONE WITH COMMON MATERIALS AND CONTAMINANTS WITH WHICH THE MATERIAL MAY
REASONBLY COME INTO CONTACT.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NONE.
Conditions to Avoid Polymerization:WILL NOT OCCUR.
Disposal
Waste Disposal Methods:DISCHARGE, TREATMENT, OR DISPOSAL MAY BE SUBJECT
TO NATIONAL, STATE, OR LOCAL LAWS. FLUSH TO SEWER WITH LARGE
AMOUNTS OF WATER.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.